| Diamond
Control Board - The unique Diamond board uses state
of the art technology combined with easy of use to provide
many exceptional new features that cannot be found on any
other board.
2
Wire Maser/Slave - The Diamond board uses a unique
Master/Slave system that requires only two wires.
Motor
Brake - If the on position is selected electric gate
opener, the gate will stop instantly when it reaches the
limit switches. This is essential on uphill/downhill applications
and on all Fail Safe operations.
One
Pass - This tailgating feature works with the reverse
loop to allow only one car to pass. After the car passes
the gate closes instantly, if a second car approaches
the gate stops, and resumes closing once the car has left.
Stop-Reverse
- This radio feature allows the transmitter to work as
a three-button station and is useful for partial opening.
The first command of the electric gate opener opens the
gate, the second stops the gate, and the third command
will close the gate.
Timer
- The adjustable timer can be set from 1 to 60 seconds,
with a maximum run time of 60 seconds.
Overload
- If the motor reaches the stall amp for 3 seconds,
it will automatically shut down.
Receiver
- The receiver terminal is mounted on the control box
for easy installation and is pre-wired for a 3-wire or
4-wire receiver.
Stainless
Steel Access Door - Eagle offers a full access to
the control board through the locking stainless steel
door on its electric gate openers.
|
ERD
- If the gate hits an obstruction while closing, it will
re-open. If it hits an obstruction while opening, it will
stop, reverse 6 inches and stop again. The sensitivity
is adjustable separately for the open and close cycles.
Global
Inputs - The Diamond board's Global Inputs include
key switch, keypad, exit loop, phantom loop, reverse loop,
edge sensor, open, stop, and close.
Outputs
- Outputs include on board 24 VDC for MAG Lock, alarm,
and 24 VAC auxiliary power.
Safety
Alarm - If the gate hits an object twice while closing
or opening, the electric gate opener will shut down for
5 minutes. On the Diamond board you have two options for
reset mode. Selecting the off position will require a
manual reset of the board if the previous happens. However,
by selecting the on position, the system will automatically
reset itself.
120
VAC Power Outlets - The operator contains two 120
VAC Power Outlets for the users convenience.
Power
on/off Switch - The operator has an easily accessible
power disconnect switch that allows for easy installation
and service.
No
Pinch Arm - This safety features prohibits the arm
from extending past the operator's body when the arm is
in the fully extended position.
Gate
Opening - Can operate to either the left or right
side.
|